Coolblast Fans

Coolblast Fan Unit Uncontrolled, 3-6 fans

Fan unit for vertical cooling of modules in 19? racks

OR

Coolblast Fan Unit Thermostat Controlled, 3-6 fans

Fan unit for vertical cooling of modules in 19? racks. Fan function (ON/OFF) thermostat controlled, setting from 0?C to 60?C

Coolblast Fan Unit Speed Controlled, 3-6 fans

  • Vertical cooling of modules in 19? racks
  • Reference temperature can be set (20?C to 55?C)
  • Fan speed regulation 30% to 100% of the nominal speed, with sensor failure 100% speed
  • Individual fan monitoring
  • Digital alarm output for excess temperature alarm and fan failure
  • Optical status display for O.K., excess temperature and fan failure
  • Acoustic warning

Chassis rails are recommended for mounting. Chassis rails are required with CoolBlast 6-way.

Coolblast Technical Information:
Material:          
Sheet steel, high-grade steel grid
Finish/Colour: Housing, zinc-passivated
                        Front panel, powder-coated, smooth in RAL 7035 light-grey
Supplied:         Assembled, wired and tested

Filter Fan
  • For specific use with hot spots
  • Also suitable for later mounting, quick and easy
  • The filter mats provide high filtering-out properties, are easily exchanged and can be cleaned
  • The fans do not require maintenance and their value is especially emphasised by their long lifespan and low noise factor
  • Airflow: blowing in the rack (pre-setting) - Can be used as blowing-out or taking-in

 
Material:                Heat-resistant ABS plastic, UL 94 V-0
Colour:                   RAL 7035, light-grey
Approvals:             CE Symbol
Protection rating:  IP 54


CoolAdd - Cooling of up to 8000 watts

CoolAdd is a further innovation in combating the problems of over-heated computer centres.
The hot output air generated by the high-performance servers is intelligently cooled and the room?s thermal management system is therefore noticeably relieved.

CoolAdd? is an easy to mount add-on set that simply replaces the rear doors of the server rack and connects to the computer centre?s thermal management infrastructure.

Technical data
For server racks:
from 2000 mm height
from 600 mm wide
Depth 160 mm

Balancing out thermal loads in computer centres. Effective cooling of up to 8000 Watts under the following conditions/temperatures:

Server output air: 35? C, Tserver out

CoolAdd air outlet temperature: 22? C, TCoolAdd out
Cooling water feed: 14? C, Twater feed
Cooling water return: 20? C, Twater return
4 fans / n+1 redundancy


CoolAdd replaces the server rack?s rear doors and is also adapted to the existing rack?s structure.

A connection to the computer centre?s cold water system is required.The air/water heat exchanger is positioned in the fixed installed part of the upgrade kit and is connected to the server rack via the frame. Four fans are integrated into the rear door, which provides access to the cabling for the rack components.

CoolAdd is just one of the numerous innovations of the Knurr High Density Cooling Solutions family.