Coolblast Fans
|
Coolblast Fan Unit Uncontrolled, 3-6 fans
Fan unit for vertical cooling of modules in 19? racks
OR
Coolblast Fan Unit Thermostat Controlled, 3-6 fans
Fan unit for vertical cooling of modules in 19? racks. Fan function (ON/OFF) thermostat controlled, setting from 0?C to 60?C
|
|

|
Coolblast Fan Unit Speed Controlled, 3-6 fans
- Vertical cooling of modules in 19? racks
- Reference temperature can be set (20?C to 55?C)
- Fan speed regulation 30% to 100% of the nominal speed, with sensor failure 100% speed
- Individual fan monitoring
- Digital alarm output for excess temperature alarm and fan failure
- Optical status display for O.K., excess temperature and fan failure
- Acoustic warning
Chassis rails are recommended for mounting. Chassis rails are required with CoolBlast 6-way. |
Coolblast Technical Information: Material: Sheet steel, high-grade steel grid Finish/Colour: Housing, zinc-passivated Front panel, powder-coated, smooth in RAL 7035 light-grey Supplied: Assembled, wired and tested
Filter Fan
- For specific use with hot spots
- Also suitable for later mounting, quick and easy
- The filter mats provide high filtering-out properties, are easily exchanged and can be cleaned
- The fans do not require maintenance and their value is especially emphasised by their long lifespan and low noise factor
- Airflow: blowing in the rack (pre-setting) - Can be used as blowing-out or taking-in
Material: Heat-resistant ABS plastic, UL 94 V-0 Colour: RAL 7035, light-grey Approvals: CE Symbol Protection rating: IP 54
|
 |
CoolAdd - Cooling of up to 8000 watts
CoolAdd is a further innovation in combating the problems of over-heated computer centres. The hot output air generated by the high-performance servers is intelligently cooled and the room?s thermal management system is therefore noticeably relieved.
CoolAdd? is an easy to mount add-on set that simply replaces the rear doors of the server rack and connects to the computer centre?s thermal management infrastructure.
Technical data For server racks: from 2000 mm height from 600 mm wide Depth 160 mm
Balancing out thermal loads in computer centres. Effective cooling of up to 8000 Watts under the following conditions/temperatures:
Server output air: 35? C, Tserver out
CoolAdd air outlet temperature: 22? C, TCoolAdd out Cooling water feed: 14? C, Twater feed Cooling water return: 20? C, Twater return 4 fans / n+1 redundancy
|
 |
CoolAdd replaces the server rack?s rear doors and is also adapted to the existing rack?s structure.
A connection to the computer centre?s cold water system is required.The air/water heat exchanger is positioned in the fixed installed part of the upgrade kit and is connected to the server rack via the frame. Four fans are integrated into the rear door, which provides access to the cabling for the rack components.
CoolAdd is just one of the numerous innovations of the Knurr High Density Cooling Solutions family. |
|
|
|
|
|
|
|